{"id":1891,"date":"2025-01-16T09:23:54","date_gmt":"2025-01-16T01:23:54","guid":{"rendered":"https:\/\/onerovalve.com\/?p=1891"},"modified":"2025-01-16T09:23:59","modified_gmt":"2025-01-16T01:23:59","slug":"api-605-vs-asme-b16-47","status":"publish","type":"post","link":"https:\/\/www.onerovalve.com\/es\/blog\/comparison\/api-605-vs-asme-b16-47\/","title":{"rendered":"API 605 vs ASME B16.47: Est\u00e1ndares de bridas para v\u00e1lvulas de bola industriales"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Los sistemas de tuber\u00edas industriales requieren est\u00e1ndares de compatibilidad, seguridad y rendimiento precisos y confiables. Dos est\u00e1ndares esenciales para bridas de gran di\u00e1metro son API 605 y ASME B16.47, que abordan el dise\u00f1o y la aplicaci\u00f3n de bridas en sistemas industriales. \u00bfQu\u00e9 son estos est\u00e1ndares y en qu\u00e9 se diferencian? Esta gu\u00eda describe claramente sus principales diferencias y usos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00bfQu\u00e9 son API 605 y ASME B16.47?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Norma API 605<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">API 605 fue una especificaci\u00f3n creada por el Instituto Americano del Petr\u00f3leo (API) para<a href=\"https:\/\/forgedcomponents.com\/what-are-large-diameter-flanges\/\"> Bridas de acero de gran di\u00e1metro.<\/a> Cubr\u00eda bridas de 26\u2033 a 60\u2033 de di\u00e1metro, principalmente para <a href=\"https:\/\/tameson.com\/pages\/flange-rating\">Clase 150 y Clase 300 <\/a>Clasificaciones de presi\u00f3n. Debido a su compatibilidad con sistemas de tuber\u00edas espec\u00edficos, estas bridas se utilizaron ampliamente en tuber\u00edas de petr\u00f3leo, gas y petroqu\u00edmicas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sin embargo, la <strong>Norma API 605<\/strong> Desde entonces ha sido reemplazado por bridas ASME B16.47 Serie B, que proporcionan una estandarizaci\u00f3n mejorada en todas las industrias.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Norma ASME B16.47<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">ASME B16.47, desarrollado por <a href=\"https:\/\/www.asme.org\/\">Sociedad Estadounidense de Ingenieros Mec\u00e1nicos (ASME)<\/a>, regula bridas de acero de gran di\u00e1metro. Se divide en dos series:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Serie A:<\/strong> Estas bridas tienen su origen en la<a href=\"https:\/\/www.octalflange.com\/mss-sp-44\/#:~:text=44%20Flange%20Specification-,MSS%20SP%2D44%20Flange%20Specification,to%2080%20ksi%20(F80).\"> Especificaci\u00f3n del MSS SP-44<\/a> y est\u00e1n dise\u00f1ados para usos industriales de alto estr\u00e9s. Son m\u00e1s gruesos, m\u00e1s pesados y ofrecen mayor resistencia.<\/li>\n\n\n\n<li><strong>Serie B<\/strong>:Estas bridas se basan en la norma API 605, que enfatiza la construcci\u00f3n liviana y la rentabilidad para aplicaciones menos exigentes. Se utilizan a menudo en sistemas de tuber\u00edas que requieren una presi\u00f3n menos estricta.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ambas series garantizan consistencia en dimensiones, clasificaciones de presi\u00f3n y especificaciones de materiales.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Diferencias clave entre API 605 y ASME B16.47<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Antecedentes hist\u00f3ricos<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>API 605: Esta norma fue creada para bridas livianas en tuber\u00edas y fue popular porque era rentable y f\u00e1cil de usar. Sin embargo, fue reemplazada por ASME B16.47 Serie B, que actualiz\u00f3 y mejor\u00f3 sus reglas.<\/li>\n\n\n\n<li>ASME B16.47: Esta norma combin\u00f3 varios requisitos de bridas para crear un sistema \u00fanico que funciona para diferentes industrias. Ampli\u00f3 la norma API 605 al agregar opciones m\u00e1s resistentes y flexibles.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Comparaci\u00f3n de la Serie A y la Serie B<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Serie A (MSS-SP-44)<\/strong>:Estas bridas son m\u00e1s gruesas y resistentes, dise\u00f1adas para entornos dif\u00edciles como sistemas de alta presi\u00f3n. Se suelen utilizar en proyectos de nueva construcci\u00f3n con condiciones dif\u00edciles, como vibraciones o cambios de temperatura.<\/li>\n\n\n\n<li><strong>Serie B (API 605)<\/strong>:Estas bridas son m\u00e1s livianas y delgadas, y se enfocan en el ahorro de peso y costos. Son ideales para modernizaciones o proyectos donde la reducci\u00f3n de peso es importante. Sin embargo, utilizan m\u00e1s pernos peque\u00f1os que la Serie A.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Usos en diferentes aplicaciones<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Las bridas API 605 se utilizan principalmente en sistemas de tuber\u00edas, especialmente en petr\u00f3leo y gas, donde el peso ligero y el bajo coste son importantes.<\/li>\n\n\n\n<li>Las bridas ASME B16.47 son comunes en plantas petroqu\u00edmicas, plantas de abastecimiento de agua e industrias de generaci\u00f3n de energ\u00eda. La serie A es mejor para sistemas de alta presi\u00f3n, mientras que la serie B es mejor para usos m\u00e1s livianos y menos exigentes.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Dise\u00f1o de pernos y orificios<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Serie A:<\/strong> Utiliza menos pernos y m\u00e1s grandes, lo que lo hace fuerte y confiable para aplicaciones de alto estr\u00e9s.<\/li>\n\n\n\n<li><strong>Serie B: <\/strong>Utiliza pernos m\u00e1s peque\u00f1os, lo que ayuda a reducir el movimiento en la brida y es adecuado para sistemas livianos.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para que sea m\u00e1s f\u00e1cil comprender las diferencias entre API 605 y ASME B16.47, la siguiente tabla compara sus caracter\u00edsticas principales. Esta vista en paralelo destaca las ventajas de cada norma, lo que le ayudar\u00e1 a elegir la que mejor se adapte a sus necesidades:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Caracter\u00edstica<\/strong><\/td><td><strong>API 605<\/strong><\/td><td><strong>Normativa ASME B16.47<\/strong><\/td><\/tr><tr><td><strong>Estado<\/strong><\/td><td>Reemplazado por ASME B16.47<\/td><td>Activo<\/td><\/tr><tr><td><strong>Serie<\/strong><\/td><td>N \/ A<\/td><td>Serie A y B<\/td><\/tr><tr><td><strong>Orificios para pernos<\/strong><\/td><td>M\u00e1s peque\u00f1os, m\u00e1s numerosos<\/td><td>Serie A: Menos, m\u00e1s grandesSerie B: M\u00e1s peque\u00f1as, m\u00e1s numerosas<\/td><\/tr><tr><td><strong>Opciones de materiales<\/strong><\/td><td>Acero carbono<\/td><td>Acero al carbono, acero inoxidable y aleaciones.<\/td><\/tr><tr><td><strong>Aplicaciones<\/strong><\/td><td>Sistemas de tuber\u00edas<\/td><td>Serie A: Aplicaciones de alto estr\u00e9sSerie B: Sistemas de tuber\u00edas<\/td><\/tr><tr><td><strong>Costo<\/strong><\/td><td>Generalmente m\u00e1s bajo<\/td><td>Serie A: Superior por peso y tama\u00f1oSerie B: Comparable a API 605<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u00bfC\u00f3mo elegir la brida adecuada?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Al elegir el est\u00e1ndar de brida adecuado para v\u00e1lvulas de bola industriales, tenga en cuenta lo siguiente:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Requisitos de desempe\u00f1o<\/strong>:Evaluar las condiciones de presi\u00f3n y temperatura operacional. <strong>Bridas serie A<\/strong> Ofrecen una resistencia superior y son ideales para sistemas con necesidades de alta presi\u00f3n o calor extremo.<\/li>\n\n\n\n<li><strong>Especificaciones del proyecto<\/strong>: <strong>Serie B (API 605)<\/strong> Las bridas son adecuadas para proyectos de modernizaci\u00f3n o sistemas livianos, centr\u00e1ndose en la rentabilidad y la flexibilidad.<\/li>\n\n\n\n<li><strong>Selecci\u00f3n de materiales<\/strong>:Asegure la compatibilidad del material con su aplicaci\u00f3n. Ambas normas admiten materiales de uso com\u00fan, como acero al carbono y acero inoxidable, lo que garantiza la durabilidad y el rendimiento.<\/li>\n\n\n\n<li><strong>Configuraci\u00f3n de dise\u00f1o<\/strong>:Elija la Serie A para pernos m\u00e1s grandes y menos numerosos, adecuados para usos intensivos. Opte por <strong>Serie B<\/strong> cuando se necesita un ajuste m\u00e1s ajustado y liviano con pernos m\u00e1s peque\u00f1os.<\/li>\n\n\n\n<li><strong>Cumplimiento y certificaci\u00f3n<\/strong>:Confirme que las bridas cumplan con los est\u00e1ndares de la industria como ASME B16.47, garantizando un funcionamiento confiable y seguro para su aplicaci\u00f3n.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Beneficios de la estandarizaci\u00f3n ASME B16.47<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Compatibilidad mejorada<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Las especificaciones uniformes de ASME B16.47 garantizan un rendimiento consistente en diversas industrias, lo que permite una integraci\u00f3n perfecta con otros componentes de tuber\u00edas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Seguridad y confiabilidad<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Los rigurosos criterios de dise\u00f1o de la norma garantizan un alto rendimiento bajo fluctuaciones de presi\u00f3n y temperatura, reduciendo el riesgo de falla del sistema.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Versatilidad<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Con opciones de Serie A y B, ASME B16.47 se adapta a diversas necesidades, desde entornos de alto estr\u00e9s hasta reemplazos de tuber\u00edas sensibles a los costos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Conclusi\u00f3n<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La norma de brida adecuada, API 605 o ASME B16.47, depende de su aplicaci\u00f3n. Si necesita bridas m\u00e1s resistentes para alta presi\u00f3n, elija la Serie A. Para soluciones livianas y rentables, la Serie B es ideal. Conocer estas diferencias lo ayudar\u00e1 a seleccionar la brida m\u00e1s confiable para su sistema de v\u00e1lvula de bola.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comprender estos aspectos le garantiza seleccionar la brida correcta para un rendimiento \u00f3ptimo. Explorar<a href=\"https:\/\/www.onerovalve.com\/es\/products\/\"> P\u00e1gina de productos de OneRoValve<\/a> Para una selecci\u00f3n completa de v\u00e1lvulas de bola y bridas industriales. Para obtener m\u00e1s ayuda, visite <a href=\"https:\/\/www.onerovalve.com\/es\/contact\/\">Nuestra p\u00e1gina de contacto de OneRoValve<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Meta descripci\u00f3n:<\/strong> Explore las diferencias entre las normas de bridas API 605 y ASME B16.47 para v\u00e1lvulas de bola industriales. Conozca su funcionalidad, aplicaciones y caracter\u00edsticas.<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Referencias<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.trupply.com\/blogs\/news\/what-is-the-difference-between-asme-b16-5-asme-b16-47-series-a-series-b-and-api-605-flanges?srsltid=AfmBOoruZitg9qFXLnW36CNqBRYyVWhcukMn_GX43rrddYgxoJnTqxDF\">\u00bfCu\u00e1l es la diferencia entre las bridas ASME B16.5, ASME B16.47 Serie A, Serie B y API 605?<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.coastalflange.com\/blog\/whats-the-difference-between-asme-b16-47-series-a-and-series-b-flanges\/\">\u00bfCu\u00e1l es la diferencia entre las bridas ASME B16.47 Serie A y Serie B?<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Industrial piping systems require precise and reliable compatibility, safety, and performance standards. Two essential standards for large-diameter flanges are API 605 and ASME B16.47, which address<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":1892,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[66],"tags":[],"class_list":["post-1891","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-comparison"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>API 605 vs ASME B16.47: 10 Differences of Flange Standards<\/title>\n<meta name=\"description\" content=\"Discover the 10 key differences between API 605 and ASME B16.47 flange standards, including applications, design, and material options. Choose the right standard for your industrial ball valve system with this comprehensive guide.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.onerovalve.com\/es\/blog\/comparison\/api-605-vs-asme-b16-47\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"API 605 vs ASME B16.47: 10 Differences of Flange Standards\" \/>\n<meta property=\"og:description\" content=\"Discover the 10 key differences between API 605 and ASME B16.47 flange standards, including applications, design, and material options. Choose the right standard for your industrial ball valve system with this comprehensive guide.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.onerovalve.com\/es\/blog\/comparison\/api-605-vs-asme-b16-47\/\" \/>\n<meta property=\"og:site_name\" content=\"Professional ball valve manufacturer\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-16T01:23:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-16T01:23:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.onerovalve.com\/wp-content\/uploads\/2025\/01\/unnamed1-67885f76d7b28.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"ouqiuadmin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"ouqiuadmin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/\"},\"author\":{\"name\":\"ouqiuadmin\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#\\\/schema\\\/person\\\/d8a543fd1c3677e64304f7884e7d6cb6\"},\"headline\":\"API 605 vs ASME B16.47: Flange Standards for Industrial Ball Valves\",\"datePublished\":\"2025-01-16T01:23:54+00:00\",\"dateModified\":\"2025-01-16T01:23:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/\"},\"wordCount\":916,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.onerovalve.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/unnamed1-67885f76d7b28.webp\",\"articleSection\":[\"comparison\"],\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/\",\"url\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/\",\"name\":\"API 605 vs ASME B16.47: 10 Differences of Flange Standards\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.onerovalve.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/unnamed1-67885f76d7b28.webp\",\"datePublished\":\"2025-01-16T01:23:54+00:00\",\"dateModified\":\"2025-01-16T01:23:59+00:00\",\"description\":\"Discover the 10 key differences between API 605 and ASME B16.47 flange standards, including applications, design, and material options. Choose the right standard for your industrial ball valve system with this comprehensive guide.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#breadcrumb\"},\"inLanguage\":\"es-MX\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.onerovalve.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/unnamed1-67885f76d7b28.webp\",\"contentUrl\":\"https:\\\/\\\/www.onerovalve.com\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/unnamed1-67885f76d7b28.webp\",\"width\":1024,\"height\":1024},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/blog\\\/comparison\\\/api-605-vs-asme-b16-47\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.onerovalve.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"API 605 vs ASME B16.47: Flange Standards for Industrial Ball Valves\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#website\",\"url\":\"https:\\\/\\\/www.onerovalve.com\\\/\",\"name\":\"Industrial API ball valve manufacturer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.onerovalve.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-MX\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#organization\",\"name\":\"Professional ball valve manufacturer\",\"url\":\"https:\\\/\\\/www.onerovalve.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/onerovalve.com\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/633ea0f8147707eb19b6907793fa651.jpg\",\"contentUrl\":\"https:\\\/\\\/onerovalve.com\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/633ea0f8147707eb19b6907793fa651.jpg\",\"width\":109,\"height\":74,\"caption\":\"Professional ball valve manufacturer\"},\"image\":{\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.onerovalve.com\\\/#\\\/schema\\\/person\\\/d8a543fd1c3677e64304f7884e7d6cb6\",\"name\":\"ouqiuadmin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-MX\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/06fd310942ad43780e5b1139ff9d9e76b62363551f5ecc503a90569112f1ef7b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/06fd310942ad43780e5b1139ff9d9e76b62363551f5ecc503a90569112f1ef7b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/06fd310942ad43780e5b1139ff9d9e76b62363551f5ecc503a90569112f1ef7b?s=96&d=mm&r=g\",\"caption\":\"ouqiuadmin\"},\"sameAs\":[\"http:\\\/\\\/ouqiu.bluewhale.love\"],\"url\":\"https:\\\/\\\/www.onerovalve.com\\\/es\\\/author\\\/ouqiuadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"API 605 vs ASME B16.47: 10 diferencias entre los est\u00e1ndares de bridas","description":"Descubra las 10 diferencias clave entre las normas de bridas API 605 y ASME B16.47, incluidas las aplicaciones, el dise\u00f1o y las opciones de materiales. Elija la norma adecuada para su sistema de v\u00e1lvulas de bola industriales con esta gu\u00eda completa.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.onerovalve.com\/es\/blog\/comparison\/api-605-vs-asme-b16-47\/","og_locale":"es_MX","og_type":"article","og_title":"API 605 vs ASME B16.47: 10 Differences of Flange Standards","og_description":"Discover the 10 key differences between API 605 and ASME B16.47 flange standards, including applications, design, and material options. Choose the right standard for your industrial ball valve system with this comprehensive guide.","og_url":"https:\/\/www.onerovalve.com\/es\/blog\/comparison\/api-605-vs-asme-b16-47\/","og_site_name":"Professional ball valve manufacturer","article_published_time":"2025-01-16T01:23:54+00:00","article_modified_time":"2025-01-16T01:23:59+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/www.onerovalve.com\/wp-content\/uploads\/2025\/01\/unnamed1-67885f76d7b28.webp","type":"image\/webp"}],"author":"ouqiuadmin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"ouqiuadmin","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#article","isPartOf":{"@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/"},"author":{"name":"ouqiuadmin","@id":"https:\/\/www.onerovalve.com\/#\/schema\/person\/d8a543fd1c3677e64304f7884e7d6cb6"},"headline":"API 605 vs ASME B16.47: Flange Standards for Industrial Ball Valves","datePublished":"2025-01-16T01:23:54+00:00","dateModified":"2025-01-16T01:23:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/"},"wordCount":916,"commentCount":0,"publisher":{"@id":"https:\/\/www.onerovalve.com\/#organization"},"image":{"@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#primaryimage"},"thumbnailUrl":"https:\/\/www.onerovalve.com\/wp-content\/uploads\/2025\/01\/unnamed1-67885f76d7b28.webp","articleSection":["comparison"],"inLanguage":"es-MX","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/","url":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/","name":"API 605 vs ASME B16.47: 10 diferencias entre los est\u00e1ndares de bridas","isPartOf":{"@id":"https:\/\/www.onerovalve.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#primaryimage"},"image":{"@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#primaryimage"},"thumbnailUrl":"https:\/\/www.onerovalve.com\/wp-content\/uploads\/2025\/01\/unnamed1-67885f76d7b28.webp","datePublished":"2025-01-16T01:23:54+00:00","dateModified":"2025-01-16T01:23:59+00:00","description":"Descubra las 10 diferencias clave entre las normas de bridas API 605 y ASME B16.47, incluidas las aplicaciones, el dise\u00f1o y las opciones de materiales. Elija la norma adecuada para su sistema de v\u00e1lvulas de bola industriales con esta gu\u00eda completa.","breadcrumb":{"@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#breadcrumb"},"inLanguage":"es-MX","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/"]}]},{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#primaryimage","url":"https:\/\/www.onerovalve.com\/wp-content\/uploads\/2025\/01\/unnamed1-67885f76d7b28.webp","contentUrl":"https:\/\/www.onerovalve.com\/wp-content\/uploads\/2025\/01\/unnamed1-67885f76d7b28.webp","width":1024,"height":1024},{"@type":"BreadcrumbList","@id":"https:\/\/www.onerovalve.com\/blog\/comparison\/api-605-vs-asme-b16-47\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.onerovalve.com\/"},{"@type":"ListItem","position":2,"name":"API 605 vs ASME B16.47: Flange Standards for Industrial Ball Valves"}]},{"@type":"WebSite","@id":"https:\/\/www.onerovalve.com\/#website","url":"https:\/\/www.onerovalve.com\/","name":"Fabricante de v\u00e1lvulas de bola API industriales","description":"","publisher":{"@id":"https:\/\/www.onerovalve.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.onerovalve.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-MX"},{"@type":"Organization","@id":"https:\/\/www.onerovalve.com\/#organization","name":"Fabricante profesional de v\u00e1lvulas de bola","url":"https:\/\/www.onerovalve.com\/","logo":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/www.onerovalve.com\/#\/schema\/logo\/image\/","url":"https:\/\/onerovalve.com\/wp-content\/uploads\/2024\/08\/633ea0f8147707eb19b6907793fa651.jpg","contentUrl":"https:\/\/onerovalve.com\/wp-content\/uploads\/2024\/08\/633ea0f8147707eb19b6907793fa651.jpg","width":109,"height":74,"caption":"Professional ball valve manufacturer"},"image":{"@id":"https:\/\/www.onerovalve.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.onerovalve.com\/#\/schema\/person\/d8a543fd1c3677e64304f7884e7d6cb6","name":"administrador de ouqiu","image":{"@type":"ImageObject","inLanguage":"es-MX","@id":"https:\/\/secure.gravatar.com\/avatar\/06fd310942ad43780e5b1139ff9d9e76b62363551f5ecc503a90569112f1ef7b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/06fd310942ad43780e5b1139ff9d9e76b62363551f5ecc503a90569112f1ef7b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/06fd310942ad43780e5b1139ff9d9e76b62363551f5ecc503a90569112f1ef7b?s=96&d=mm&r=g","caption":"ouqiuadmin"},"sameAs":["http:\/\/ouqiu.bluewhale.love"],"url":"https:\/\/www.onerovalve.com\/es\/author\/ouqiuadmin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/posts\/1891","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/comments?post=1891"}],"version-history":[{"count":1,"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/posts\/1891\/revisions"}],"predecessor-version":[{"id":1893,"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/posts\/1891\/revisions\/1893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/media\/1892"}],"wp:attachment":[{"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/media?parent=1891"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/categories?post=1891"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.onerovalve.com\/es\/wp-json\/wp\/v2\/tags?post=1891"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}